CL17sc Colorimetric Chlorine Analyser with Pressure Regulator Installation Kit, w/o Reagents

CL17sc Colorimetric Chlorine Analyser with Pressure Regulator Installation Kit, w/o Reagents
Product #: 8574500
Unit Price Contact Us
Available

Maintenance made easy

The CL17sc reduces your routine maintenance touch time with programmable alerts, simplified tubing replacement, and step-by-step maintenance instructions.

Peace of mind through comprehensive diagnostics

With upgraded features like a flow meter, colorimeter window, multi-colour status light, and predictive diagnostic software, you know your instrument is operating as intended.

Expanded connectivity. Increased flexibility.

By pairing the CL17sc with Hach’s SC controller platform, your options increase significantly: internal data logging; external analogue and digital communication alternatives; and multi-parameter instrument flexibility.

The CL17sc is compliant with US EPA regulation 40 CFR 141.74. Both Method 4500-CL G and Method 334.0 can be used for measuring residual chlorine in drinking water.

What's in the box

CL17sc Chlorine Analyser with Pressure Regulator Installation Kit, and European User Manual. User provides screws and/or anchors for mounting.
Hach SC Controller and Reagents are not included, they are sold separately.

Specifications

Accuracy: ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂
± 10% from 5 - 10 mg/L Cl₂
Air purge: Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar maximum
Alerts: Low and high chlorine. Dirty cell. Low and high sample flow.
Certifications: CE compliant with: EN 61326-1, CISPR 11, EN 50581
ACMA RCM
South Korea KC Certificate
North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
Controller compatibility: SC200, SC1000, SC4500. All controllers sold separately
Cycle time: 2.5 minutes
Detection limit: 0.03 mg/L
Dimensions (H x W x D): 342 mm x 329 mm x 177 mm
Drain: ½-inch ID flexible hose
Enclosure waterproof rating: IP66
Flow rate: 60 - 200 mL/min through the instrument
Inlet: ¼-inch OD polyethylene tube, quick-disconnect fitting
Inlet pressure: 0.3 - 5.2 bar supplied to Y-strainer
0.1 - 0.3 bar supplied to analyser
Installation Kit: Pressure Regulator Installation Kit
Interferences: Other oxidising agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
Light source: LED, measurement at 510 nm, 1 cm light pathlength
Measuring range: 0 - 10 mg/L Cl₂
Mounting: Wall mount
Operating humidity: 0 - 90% relative humidity, non-condensing
Operating temperature range: 5 - 40 °C
Parameter: Chlorine, free; Chlorine, total residual
Power requirements (Voltage): 12 VDC, 400 mA maximum (supplied by the controller)
Reagent consumption: 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
Sample requirements: Y-strainer filtration with 40-mesh screen or higher
Sample temperature: 5 - 40 °C
Warranty: 24 months
Weight: 4.1 kg
What's included?: CL17sc Chlorine Analyser with Pressure Regulator Installation Kit, and European User Manual. User provides screws and/or anchors for mounting.
Hach SC Controller and Reagents are not included, they are sold separately.